FEATURES AND BENEFITS:
Multiple load cell configuration--
It can store configuration data for up to six loadcells or torque
measurement devices. The instrument moves rapidly from job to job
without recalibration.
Full range of test values--
FI-127 will display a Peak Capture value or Peak Capture plus a
First Peak value. The instrument can take a series of readings and
display Average Force Over Time, or it can display Over, Under and
Accept load values.
Data capture function--
Stores a sequence of load cell data which the instrument can feed
accumulated information to a built-in data base. Data base can store
up to 204 consecutive test values for print or later download.
Easy system interface--
It can drive relay coils or send signals to other instruments,
computers or PLCs. Its outputs can sound alarms or light warning
lights or shut down a system. Its seven inputs can automate data
collection from a testing machine or provide an accessory switch to
control any of the key pad functions
|
| SPECIFICATION
Display:
Eight digits, 0.8-inch high, green, seven-segment
LED with 8 decimal points
LED Annunciators:
Display: Force, Peak, 1st Peak, Tension, Compress
Default units of measure: lbf, kgf, N
Status: Motion, Center of Zero, Data Send
Configurable: Under, Accept, Over
Programmable selections:
Zero range, peak,first peak, data capture,
motion detection, 10-point linearization
Analog input range: ±0.2 to ±5 mV/V
Loadcell excitation: ± 5 VDC at 343 mA
Supports up to twelve 350-ohm loadcells
Analog to digital conversion rate: 60 times per second
Linearity adjustment:The instrument may be
calibrated
for up to six different load cells. Each loadcell may be
calibrated at two to ten points, providing best fit
linearization. 35 total calibration pints available.
Accuracy:
Linearity: ±0.005% of capacity
Span: ±5.0 ppm/°C (-40 to 60°C)
Repeatability: ±0.005% of capacity
Hysteresis: 0.005% of capacity
|
|
|
|
| |