Industrial
Data Systems Inc., proudly introduces the addition of the new IDS 430
digital weight indicator to the 400 series indicator line.
The
versatility of the IDS 430 allows you to perform a number of tasks.
These range from basic weighing operations to more complex tasks such as
controlling batches, check-weighing, or bulk -loading.
The
IDS 430 includes, 16 programmable instructions (macros), and
provides you with the capability of designing the printed record to
satisfy your specific requirements. Compact in size and weight, the system
is housed in a rugged stainless steel enclosure which can be wall
or desk mounted. The unit can be tilted to any angle to provide you with
the best possible view.
One
inch high, seven segment LED characters make it easier to read from
longer distance than most digital indicators. Brightness can be adjusted
to suit conditions. The keyboard features large keys which give you
tactile confirmation of input.
APPLICATIONS
From
gross, tare and net weighing to sophisticated trip-level event monitoring.
Seven built-in applications standard: Fill to setpoint, Check weigh,
Weigh-in Weigh-out, Manual/Auto axle or container weighing, ID tare and
total and Peak Hold. Applications are unlimited for the user who is
capable of writing a basic program. For those who prefer turnkey products,
Industrial Data Systems offers a constantly growing number of standard
applications at no additional charge or custom programming is available.
PROGRAM
DESCRIPTION
The
basic weighing mode features push-button zero, push-button tare and
keyboard tare. The display indicates the weight and scale status. The
weight data can be transmitted to a printer, scoreboard, computer, etc.
Additional functions allow the user or scale technician to program this
indicator for specific application using Scale Basic. This is done
by entering instructions into the IDS 430 using codes for addition,
subtraction, activating events, etc. An Event Monitor is
included to provide user-definable setpoints that trigger relay
outputs. The IDS 430 monitors the weight on the scale and compares it
with the setpoint level. When the weight on the scale reaches the setpoint,
a relay output is activated. The setpoints are defined in an event record
which defines how the set-point is calculated, what relay to activate, and
what other function to initiate. EZ Link, a windows-based software
program, is optionally available to enable programming on a PC and
uploading to the IDS 430.
FEATURES
Utilizes
latest Delta Sigma scale technology (60 samples per second).
Equipped with two bi-directional serial ports and one digital
port for TTL I/O control. TTL signals can be used for relay
switching to control traffic lights, alarms, bells, augers, etc. Lightning
protection suppresses voltage spikes on load cell and AC input lines.
Network capable of controlling several units from a master. Programmable
serial data output. Remote control operation. Provides Audit
Number for calibration data. Modifiable print formats to fit
any size ticket. Universal printer interface to most common printers.
OPTIONS
Input power option: 12 to 28 VDC.
Analog
Output: Provides4-20ma, 0-20ma, 0-24ma, 0-5v, 0-10v
outputs with 16-bit resolution for process control.
Relay
Module: Housed inside a NEMA enclosure, the relay
module accommodates 4 optically-isolated, solid-state relays inputs or
outputs. Relay configurations vary depending upon the application, consult
the factory.
EZ
Link: A windows software program which allows you to
perform all configuration and application programming on your computer and
upload it to the IDS 430. The IDS 430 can download information to the EZ
Link as well. With EZ Link, you can configure scale parameters I/O ports,
print formats, passwords, and set-points. You program with "event
-driven programming". EZ Link includes an editor to facilitate
writing the program and a compiler to check for errors.
COMMUNICATIONS
Serial
Port 1: ...............................
RS232 or 20ma current loop.
Serial Port 2:
............................... RS232 RS485 or
20ma current loop.
Digital Port:
............................... 3TTL
inputs and 3 TTL outputs.
SPECIFICATIONS
GENERAL
SPEC.
-
Power:
120 VAC ±10%, 50/60 Hz Standard, 230 VAC ±10%,
50/60Hz available or 12 VDC.
-
Power
Consumption operating: 10 watts @ 115VAC, 6
watts @ 12VDC.
-
Size:
7.63 inches high, 8.56 inches wide, and 2 inches deep (19.38 x 21.74 x
5.08 cm).
-
Weight:
6 lbs (2.72 kg).
-
Operating
Temperature: -10 to +40 oC.
SCALE
SPEC.
-
Display:
............................................
1-inch x 6-digit numeric, 5-LED
status
indicators.
-
Keyboard:
......................................
Sealed with tactile feel.
-
Display
Graduations: ....................
200,000 industrial; 10,000 HB44.
-
Display
increments: ........................
1, 2, 5, 10, 20, 50.
-
Decimal
Point: .................................
0 to 4 decimal places.
-
Internal
Graduations: .....................
1,024,000.
-
Conversation
Rate: ......................... 60/sec.
@ 60 HZ line frequency.
-
Signal
Sensitivity: ............................ 0.1
uV/grad (min).
-
Signal
Range: ..................................
0.5 mv/V to 6mv/V
-
Load
Cell Excitation:
...................... 10 V
Download data sheet